福祿克SImpliFiber PRO光纖測試儀的精確度(FTK1000,F(xiàn)TK2000,F(xiàn)TK1450)
文章出處:深圳市連訊達(dá)電子技術(shù)開發(fā)有限公司
人氣:-發(fā)表時(shí)間:2015-07-08 15:17:00
測試設(shè)備廠商通過“線性”來描寫光功率計(jì)的準(zhǔn)確度,線性是光功率計(jì)知道的參數(shù),福祿克SImpliFiber PRO光功率計(jì)(FTK1000,F(xiàn)TK2000,F(xiàn)TK1450)的線性描述如下:
Power measurement linearity
850 nm: ±0.2 dB for power from 0 dBm to -45 dBm, ±0.25 dB for power < -45 dBm.
1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm: ±0.1 dB for power from 0 dBm to -55 dBm. ±0.2 dB for power > 0 dBm and < -55 dBm.
同時(shí)光源的穩(wěn)定性也是十分重要的。福祿克SImpliFiber PRO光功率計(jì)(FTK1000,F(xiàn)TK2000,F(xiàn)TK1450)光源文檔性描述如下:
Power output stability
850/1300nm source: ±0.1 dB over 8 hours
1310/1550 nm source: ±0.25 dB over 8 hours
At 23°C ±2°C (73°F ±3.6°F), after 5 minutes of warm-up time.
此文關(guān)鍵字:SImpliFiber PRO,光功率計(jì),FTK1000,FTK2000,FTK1450