Port or cabling short Autotest not available - CableIQ
Port or cabling short Autotest not available - CableIQ
You may receive the following message:
The Autotest may not run if the tester is connected to a data port, detects voltage or a short on the cabling. If any of these three instances occur, you may see the screen above.
Solution
Rotate the dial to DISCOVER. The CableIQ should be able to tell you why it cannot run an Autotest. In this example, the CableIQ was connected to an active port:
Here we see that the port the CableIQ is connected to is capable for 10BASE-T, 100BASE-T is Full Duplex mode and is 41.5 m from the CableIQ.
What if the warning "Port or Cabling short Autotest not available" occurs while connecting the Cable IQ over a cable to the CIQ-WM far end adapter?
This is an indication that the far end adapter may need to be replaced.
You can validate the RJ45 port on the Cable IQ by leaving the cable attached and turn the dial to DISCOVER. If the RJ45 port is good, you should be able to press F1 and see the pair lengths on the attached cable. It is normal to see a small variance on pair lengths between the pairs, as the twist rates are different. If you see 0 length for a pair, it indicates a problem with the RJ45 port on the Cable IQ; contact the Service Center for repair.
If you have any of the additional office identifiers for Cable IQ (CIQ-IDK24 or CIQ-IDK57), try using one at the far end of the cable with an RJ45 coupling and see it it works to run the Autotest.
Otherwise, replace your CIQ-WM far end adapter.
同類文章排行
- Port or cabling short Autotest not available - CableIQ
- 輕松搞定50個(gè)變送器的那些小物件
- 帶你了解標(biāo)準(zhǔn)鉑電阻溫度計(jì)
- FLUKE設(shè)備使用中 3db原則說明
- PoE Load Testing: Advanced Troubleshooting for Your PoE Systems
- 福祿克F319鉗表和87V MAX工業(yè)級萬用表在鋼鐵企業(yè)生產(chǎn)中的應(yīng)用
- 福祿克F110CN萬用表在PCB(印制電路板)開發(fā)板的應(yīng)用
- FLUKE福祿克數(shù)字萬用表常見問題
- 福祿克1508絕緣電阻測試儀在新能源汽車電池包絕緣檢測的應(yīng)用
- 電壓鉗表T6-1000 PRO,電氣測試工程師實(shí)操分享
最新資訊文章
您的瀏覽歷史